 DATA S H E E T
MINIATURE SIGNAL RELAY
EC2(ND),EE2(ND) SERIES
High Insulation, High breakdown voltage, compact and lightweight, Surface mounting type
DESCRIPTION
NEC EC2 (ND) / EE2 (ND) series has based supplementary insulation for EN60950. (TUV Certified File No. R9750561)
FEATURES
TM Insulation distance : more than 2 mm TM Distance through insulation : more than 0.4 mm TM Applicable for the surge voltage standard of FCC (1500 V, 10 x 160 s) and BELLCORE (2500 V, 2 x 10 s) TM Two types for through-hole mounting (EC2 (ND) series) and surface mounting (EE2 (ND) series)
APPLICATIONS
Electronic switching systems, facsimile, modems, terminal equipment.
For Right Use of Miniature Relays
DO NOT EXCEED MAXIMUM RATINGS. Do not use relays under exceeding conditions such as over ambient temperature, over voltage and over current. Incorrect use could result in abnormal heating, damage to related parts or cause burning. READ CAUTIONS IN THE SELECTION GUIDE. Read the cautions described in NEC's "Miniature Relays" (ER0046EJ) when you choose relays for your application.
The information in this document is subject to change without notice.
Document No. ER0327EJ2V0DS00 Date Published May 1999 M Printed in Japan
(c)
1997
EC2(ND),EE2(ND) SERIES
DIMENSIONS AND PAD LAYOUTS (Unit : mm (inch))
EC2 (ND) SERIES
15.0 (0.591) MAX. 7.5 (0.296) MAX. Non-latch and Single coil latch
8 - 0.8 (0.031)
9.4(0.370) MAX.
3.2 (0.126)
0.5 (0.026) 5.08 2.54 2.54 (0.200) (0.100) (0.100)
0.25 (0.010) 5.08 (0.200)
2.54 (0.100)
4 x 2.54 (0.100)
(Bottom fiew)
Note. General tolerance : 0.2 (0.008) Dimensions in show basic size.
Note. General tolerance : 0.1 (0.004)
EE2 (ND) SERIES
10.0 MAX. (0.394)
3.0 (0.118)
15.0 MAX. (0.591)
7.5 MAX. (0.296)
1.0(0.039)
2.54(0.1)
2 x 2.54(0.1)
1.0 (0.039)
5.08 (0.200)
2-2.54 (2-0.100)
5.08 (0.200) 9.5 (0.374)
5.08 (0.200)
2-2.54 (0.100)
(Bottom view) Note 1. General torelance : 0.1 ( 0.004)
Note 1. General torelance : 0.2 (0.008)
PIN CONFIGURATIONS (bottom view)
EC2 (ND) SERIES
1 3 4 5 RS Index mark of relay direction 12 10 9 8 12 10 9 8 1 3 4 5
Non-latch type (not energized position)
Single coil latch type (reset position)
S : Coil polarity of set (operate) R : Coil polarity of reset (release)
EE2 (ND) SERIES
1
3
4
5
1
3
7.29 (0.287)
4
5
RS
Index mark of relay direction
12
10
9
8
12
10
9
8
Non-latch type (not energized position)
Single coil latch type (reset position) S : Coil polarity of set (operate) R : Coil polarity of reset (release)
MARKINGS (top view)
2 EC2-5ND
1 q Part number w Manufacturer e Country of origin r Date code 5 9717 7 4 6 t Index mark of relay direction (pin No. 1, 12) 3 y UL, CSA Marking u TUV Marking
JAPAN
2
DATA SHEET ER0327EJ2V0DS00
EC2(ND),EE2(ND) SERIES
PERFORMANCE CHARACTERISTICS
Contact Form Maximum Switching Power Contact Ratings (UL / CSA Rating) Maximum Switching Voltage Maximum Switching Current Maximum Carrying Current Minimum Contact Ratings Initial Contact Resistance Contact Material Nominal Operating Power Non-Latch Type Single Coil Latch Type 2 Form c 60 W (resistive) 220 Vdc 2A 2A 10 mVdc, 10 A 1 50 m typ. (Initial) Silver alloy with gold overlay 200 to 230 mW 100 to 170 mW Approximately 2 ms without diode Approximately 1 ms without diode 1000 M at 500 Vdc Between Open Contacts Breakdown Voltage Between Adjacent Contacts Between Coil and Contact Shock Resistance 1000 Vac for one minute (1500 V surge, 10 x 160 s 2) 1000 Vac for one minute (1500 V surge, 10 x 160 s 2) 1500 Vac for one minute (2500 V surge, 2 x 10 s 3) 735 m / s2 (75 G) (misoperating) 980 m / s2 (100 G) (destructive failure) 10 to 55 Hz at double amplitude of 3 mm (20 G) (misoperating) 10 to 55 Hz, double amplitude of 5 mm (30 G) (Destructive failure) -40 to 85C (-40 to 185F) 25 degrees at nominal coil voltage (200 mW) No-load Running specifications Load Weight 1 x 108 operations (Non-latch type) 4 1 x 107 operations (latch type) 50 Vdc 0.1 A (resistive), 1 x 106 operations at 85C 10 Vdc 10 mA (resistive), 1 x 106 operations at 85C Approximately 1.9 grams 125 VA (resistive) 250 Vac
Operate Time (Excluding Bounce) Release Time (Excluding Bounce) Insulation Resistance
Vibration Resistance
Ambient Temperature Coil Temperature Rise
1 This value is reference value in the resistance load. Minimum capacity changes depending on switching frequency and environment temperatur and the load. 2 rise time : 10 s, fall time : 160 s 3 rise time : 2 s, fall time : 10 s 4 This shows a number of operation where it can be running by which a fatal defect is not caused, and a number of operation by whicha steady characteristic is maintained is 1 x 107 times.
PART NUMBER SYSTEM EC2 - 9 S ND
ND : High insulation type Latch type Nil : Non-latch type S : Single coil latch type Nominal coil voltage 3, 4.5, 5, 6, 9, 12, 24 V EC2 series
SAFETY STANDARD AND RATING
UL Recognized (UL508) File No E73266 CSA Certificated (CSA C22.2 No 14) File No LR46266 30 Vdc, 2A (Resistive) 110 Vdc, 0.3A (Resistive) 125 Vdc, 0.5A (Resistive)
Spacing : UL114, UL478
EE2 - 5 S ND
ND : High insulation type Latch type Nil : Non-latch type S : Single coil latch type Nominal coil voltage 3, 4.5, 5, 6, 9, 12, 24 V EE2 series
TUV Certificate (EN60255 / IEC60255) No. R 9750561 Creepage and clearance of coil to contact is over than 2 mm. (According EN60950 working-voltage 250 V) Supplementary insulation class
DATA SHEET ER0327EJ2V0DS00
3
EC2(ND),EE2(ND) SERIES
NOMINAL LINEUP Non-latch Type
Nominal Coil Voltage (Vdc) 3 4.5 5 6 9 12 24 Coil Resistance () 10 % 45 101 125 180 405 720 2504 Must Operate Voltage (Vdc) 2.25 3.38 3.75 4.5 6.75 9 18 Must Release Voltage (Vdc) 0.3 0.45 0.5 0.6 0.9 1.2 2.4 at 20C Nominal operate power (mW) 200 200 200 200 200 200 230
Single-Coil Latch Type
Nominal Coil Voltage (Vdc) 3 4.5 5 6 9 12 24 Test by pulse voltage Coil Resistance () 10 % 90 203 250 360 810 960 3388 Must Operate Voltage (Vdc) 2.25 3.38 3.75 4.5 6.75 9 18 Must Release Voltage (Vdc) 2.25 3.38 3.75 4.5 6.75 9 18
at 20C Nominal operate power (mW) 100 100 100 100 100 150 170
4
DATA SHEET ER0327EJ2V0DS00
EC2(ND),EE2(ND) SERIES
TYPICAL PERFORMANCE DATA
SWITCHING CAPACITY Coil Temperarure Rise (C) 2 Switching Current (A) 1
DC Load (resistive) AC Load (resistive)
COIL TEMPERATURE RISE 50 40 30 20 10 0 100 200 300 400
0.5 0.4 0.3 0.2
0.273 A
30
100
200
250 V 220 V Applied Power (mW)
Switching Voltage (V)
OPERATE TIME Operate Time or Bounce Time at Operate (ms) Operate Time 3 Bounce Time Operate 2
1
0
100
200
300
400
500
Applied Power (mW)
Release Time or Bounce Time at Release (ms)
RELEASE TIME WITHOUT DIODE Release Time or Bounce Time at Release (ms) 3
RELEASE TIME WITH DIODE Release Time
2
Release Time
2 Bounce Time at Release 1
1 Bounce Time at Release
0
100
200
300
400
500
Applied Power (mW)
0
100
200
300
400
500
Applied Power (mW)
DATA SHEET ER0327EJ2V0DS00
5
EC2(ND),EE2(ND) SERIES
RUNNING SPECIFICATIONS (Noload)
Sample : EC2-5ND n = 10 Temperature : 25 C Drive : 5 Vdc, 50 Hz 50 % duty Make contact Break contact Contact Resistance (m) 0 1 2 5 10
7
Operate Voltage Release Voltage Operate Voltage or Release Voltage (V) 5 4 3 2 1 0 200 100 50 20 10 0
0
1
2
5
10
Number of Operations ( x 10 )
7 Number of Operations ( x 10 )
RUNNING SPECIFICATIONS (Load)
Sample : EC2-5ND n = 10 Load : 50 Vdc, 0.1 A Resistive Operate Release 5 4 3 2 1 0 Temperature : 25 C Drive : 5 Vdc, 2 Hz 50 % duty Make Break 200 100 50 20 10 0
Operate, Release Voltage (V)
0
5
10
15
4
20
Contact Resistance (m)
0
5
10
15
20
Number of Operations ( x 10 )
Number of Operations ( x 10 4 )
6
DATA SHEET ER0327EJ2V0DS00
EC2(ND),EE2(ND) SERIES
BREAKDOWN VOLTAGE
Sample : EC2-5ND (a) Between Open Contacts (n = 10 pcs) (a) Between Adjacent Contacts (n = 10 pcs)
10
Appearance Appearance
10
5
5
0
0.5
1.0
1.5
0
2.0
2.5
3.0
Breakdown voltage (kV) (a) Between Coil and Contacts 10
Appearance
Breakdown voltage (kV) (n = 25 pcs)
5
0
1.5
2.0
2.5
Breakdown voltage (kV)
MAGNETIC INTERFERENCE
Drift of Operate Voltage (%)
+40 +30 +20 +10 0
-10 -20 -30 -40
Drift of Release Voltage (%)
Max.
+40 +30 +20 +10 0
-10 -20 -30 -40
Max.
Min.
Min.
I
II
III Layout
IV
V
VI
I
II
III Layout
IV
V
VI
ON
ON
OFF
OFF
ON
OFF
2.54
ON Layout I Layout II Layout III
OFF Layout IV
ON ON ON Layout V
OFF OFF OFF Layout VI Mounting Layout (mm) Sample
2.54
DATA SHEET ER0327EJ2V0DS00
7
EC2(ND),EE2(ND) SERIES
TUBE PACKAGE gEC2 (ND), EE2 (ND)h
Dimension of Package (Unit : mm) 35 pieces / Tube Material : Polyvinyl chloride (anti-static treated)
543 1
11.9 0.3
(0.5 t)
(2.4)
15.5 0.3
(4.8)
( ) Reference
Outline of Package
Rubber stopper (Red)
Rubber stopper (Green)
Index Mark
TAPE PACKAGE gEE2 (ND)h
APPEARANCE
Top cover tape
TAPE DIMENSIONS Unit : mm (inch)
1.75(0.069)
Reel
2.0(0.079)
11.5 (0.45) 24.0(0.94)
Embossed carrying tape
400 Relays / Reel (Standard)
10(0.393)
Relay orientation mark and tape carrying direction.
Index mark of relay direction
Index mark of relay direction
Tape carrying direction
Carrying tape type Part number
L EE2........-L
R EE2........-R
8
DATA SHEET ER0327EJ2V0DS00
15.5 (0.610)
1.5 (0.06) 2.2 (0.087)
16.0(0.63)
4.0(0.157)
Max.10.9 (0.429) 0.4 (0.016)
EC2(ND),EE2(ND) SERIES
SOLDERING TEMPERATURE CONDITION
Through-hole mounting type gEC2 (ND)h q Automatic soldering * Preheating * Solder time w Manual soldering * Solder temperature : 350C max. * Solder time : 3 seconds max. Surface mounting type gEE2 (ND)h : 100C max. 1 minute max. : 10 seconds max. * Solder temperature : 250C max.
IRS Method
T max.; 235 200
Temperature (C)
175 150 30 sec. 80 sec. 200 sec.
Time
VPS Method
T max.; 215
Temperature (C)
200 max.
165 max. 100 max.
Time 60 sec. max. 60 sec. 90 sec. max.
Note: 1. Temperature profile shows printed circuit board surface temperature on the relay terminal portion. 2. Check the actual soldering condition to use other method except above mentioned temperature profiles.
DATA SHEET ER0327EJ2V0DS00
9
EC2(ND),EE2(ND) SERIES
GUIDE TO APPLICATIONS
1. When connecting coils, refer to the pin configuration to prevent misoperation or malfunction. 2. The latch type relay should be initialized at the appointed position (set or reset position) when using, and should be energized or deenergized to the specified polarity to avoid wrong operations by reversed contact state. 3. Ultrasonic cleaning is not recommended to keep contact performance reliable. Alcohol based solvents are available as proper solvents. 4. Pressurized stress on the relay cover may affect reliable operation. 5. Minimum contact load of the relay is 100 mV, 100 A. This value is a reference value in the resistance load. Minimum capacity changes depending on swiching frequency and environment temperature and the load.
10
DATA SHEET ER0327EJ2V0DS00
EC2(ND),EE2(ND) SERIES
DATA SHEET ER0327EJ2V0DS00
11
EC2(ND),EE2(ND) SERIES
No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this document. NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other liability arising from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Corporation or others. While NEC Corporation has been making continuous effort to enhance the reliability of its Electronic Conponents, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or property arising from a defect in an NEC Electronic Component, customers must incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and anti-failure features. NEC devices are classified into the following three quality grades: "Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a customer designated "quality assurance program" for a specific application. The recommended applications of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device before using it in a particular application. Standard: Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support) Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact an NEC sales representative in advance. Anti-radioactive design is not implemented in this product.


▲Up To Search▲   

 
Price & Availability of EC2-12ND

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X